Overview
The core component of the Model 167 series differential pressure sensor/transmitter is a capacitive pressure sensor, which consists of a stainless steel diaphragm with a fixed electrode forming a capacitor whose value varies with pressure. Using the company's special patented technology carefully designed sensor sensors and unique detection circuit to ensure good temperature performance and long-term stability of the product.
The Model 167 differential pressure sensor/transmitter can be used to measure differential or gauge pressure with outputs of 0-5V, 0-10V, 4-20mA, and can also be customized for other outputs. The accuracy of Model 167 was ±1.0%FS, 0.4%FS or 0.25%FS at room temperature. The temperature compensation ranges from 4 ℃ to 77℃, and the temperature effect is less than ±0.05%FS/℃.
Model 167 has excellent performance-price ratio, widely used in HVAC, environmental pollution control, clean engineering, medical instruments and equipment, oven pressurization and furnace pressure control, natural gas, gas pipe network monitoring, underground ventilation and power plant wind pressure monitoring and other fields.
Feature
★ LED pressure status display
★ DIN35mm guide rail installation
★ European pluggable terminal
★ The positive/negative pressure end can withstand at least 100kPa
overload without damage
★ With temperature compensation capacitive sensitive element, to
ensure the transmitter excellent movement State/static temperature
performance
★ Multiple pressure interfaces/output forms/installation modes are
optional
★ True zero output of voltage
★ Asymmetrical bidirectional differential pressure range is optional
★ Full protection of misconnection
★ Meet the CE standard
★ Environmental protection design, in line with ROHS standards
★ Minimum pressure range of 10Pa
Datasheet
Parameter | Standard | Special selection | Special selection |
Accuracy RSS*(under constant temperature) | ±1.0%FS | ±0.40%FS | ±0.25%FS |
nonlinearity(best fitting line) | ±0.97%FS | ±0.37%FS | ±0.24%FS |
lag | ±0.20%FS | ±0.10%FS | ±0.05%FS |
non-repeatability | ±0.10%FS | ±0.10%FS | ±0.05%FS |
Temperature effect | |||
Zero point/Full range offset(/℃) | ±0.05%FS | ±0.03%FS | ±0.02%FS |
Compensation range | 4℃ to 77℃ | ||
Maximum static pressure | 15PSI(100kPa) | ||
Overload | Both positive and negative are 15PSI(100kPa) | ||
Stability ratio | ±0.5% FS/YR | ||
Preheat | 5 seconds to reach the performance specification | ||
Installation position effect | When factory calibration, the sensor is placed vertically. In order to ensure accuracy, necessary fine tuning should be made when installing other positions at zero point |
Environmental and mechanical parameters | |
Operating temperature | -18℃ to 77℃ |
Storage temperature | -40℃ to 85℃ |
Light tube indication | No light tube light: the negative pressure is too high or the power is not connected Green light tube bright: normal operation Red/green tube lighting up simultaneously: too high forward pressure |
Electircal connection | 12-24 standard wire, 5.0mm spacing pluggable European terminals |
Pressure connection | 3/16"、φ8、φ6.5 brass tower pressure connection(optional) |
Zero adjustment | The zero point can be fine-tuned through the top adjustment hole |
Pressure medium | Air or other non-conductive gas |
Shell | Stainless steel/PC+ABSalloy,94V-0 |
Weight | 198g |
Installation | DIN35mm guide rail installation |