Differential pressure sensor/transmitter
Pressure medium: air or other non-conductive gas
Accuracy: ±1.0%,±0.4%,±0.25%
Range: unidirectional: 25 Pa to 25000 Pa/bidirectional: ±10 Pa to ±10000 Pa
Signal output: 4-20mA, 0-5Vdc, 0-10Vdc
Overload: Forward and reverse 15PSL (100KPa)
The core component of the Model 167
series differential pressure sensor/transmitter is a capacitive pressure
sensor, which consists of a stainless steel diaphragm with a fixed
electrode forming a capacitor whose value varies with pressure. Using
the company's special patented technology carefully designed sensor
sensors and unique detection circuit to ensure good temperature
performance and long-term stability of the product.
The
Model 167 differential pressure sensor/transmitter can be used to
measure differential or gauge pressure with outputs of 0-5V, 0-10V,
4-20mA, and can also be customized for other outputs. The accuracy of
Model 167 was ±1.0%FS, 0.4%FS or 0.25%FS at room temperature. The
temperature compensation ranges from 4 ℃ to 77℃, and the temperature
effect is less than ±0.05%FS/℃.
Model
167 has excellent performance-price ratio, widely used in HVAC,
environmental pollution control, clean engineering, medical instruments
and equipment, oven pressurization and furnace pressure control, natural
gas, gas pipe network monitoring, underground ventilation and power
plant wind pressure monitoring and other fields.
LED pressure status display
DIN35mm guide rail installation
European pluggable terminal
The positive/negative pressure end can withstand at least 100kPa overload without damage
With temperature compensation capacitive sensitive element, to ensure the transmitter excellent movement State/static temperature performance
Multiple pressure interfaces/output forms/installation modes are optional
True zero output of voltage
Asymmetrical bidirectional differential pressure range is optional
Full protection of misconnection
Meet the CE standard
Environmental protection design, in line with ROHS standards
Minimum pressure range of 10Pa
Parameter | Standard | Special selection | Special selection |
Accuracy RSS*(under constant temperature) | ±1.0%FS | ±0.40%FS | ±0.25%FS |
nonlinearity(best fitting line) | ±0.97%FS | ±0.37%FS | ±0.24%FS |
lag | ±0.20%FS | ±0.10%FS | ±0.05%FS |
non-repeatability | ±0.10%FS | ±0.10%FS | ±0.05%FS |
Temperature effect | |||
Zero point/Full range offset(/℃) | ±0.05%FS | ±0.03%FS | ±0.02%FS |
Compensation range | 4℃ to 77℃ | ||
Maximum static pressure | 15PSI(100kPa) | ||
Overload | Both positive and negative are 15PSI(100kPa) | ||
Stability ratio | ±0.5% FS/YR | ||
Preheat | 5 seconds to reach the performance specification | ||
Installation position effect | When factory calibration, the sensor is placed vertically. In order to ensure accuracy, necessary fine tuning should be made when installing other positions at zero point |
Environmental and mechanical parameters | |
Operating temperature | -18℃ to 77℃ |
Storage temperature | -40℃ to 85℃ |
Light tube indication | No light tube light: the negative pressure is too high or the power is not connected Green light tube bright: normal operation Red/green tube lighting up simultaneously: too high forward pressure |
Electircal connection | 12-24 standard wire, 5.0mm spacing pluggable European terminals |
Pressure connection | 3/16"、φ8、φ6.5 brass tower pressure connection(optional) |
Zero adjustment | The zero point can be fine-tuned through the top adjustment hole |
Pressure medium | Air or other non-conductive gas |
Shell | Stainless steel/PC+ABSalloy,94V-0 |
Weight | 198g |
Installation | DIN35mm guide rail installation |