Senba Sensing

Senba SensingStock Code:300701Focus on PIR R&D manufacturing over 19years

Senba Sensing

+86-755-82594732
Pyroelectric Infrared Sensor

Pyroelectric Infrared Sensor

Home > Products > Pyroelectric Infrared Sensor

NS612

Pyroelectric Infrared Sensor

PROD Model: NS612

Window Size: 3*4mm

Output Signal:High and low level output

Sensing Distance: 10M (lens SB-F-02)

See lens selection for different distances

Sensing Angle: 120° (horizontal direction)

Working Voltage: 2.2-3.7V

Static Power Consumption: <11uA

General Description

NS612 is a type of PIR sensor which
integrates a digital control circuit and a human detection sensor in an
electromagenetic shielding housing.The human body detection sensor
couples the sensed human movement signal to the digital intelligent
integrated circuit chip through a very high impedance differential input
circuit, and the digital intelligent integrated circuit converts the
signal into an ADC digital signal.When the PIR signal exceeds the
selected digital threshold, there is a timed REL level output. OEN
enable terminal enables REL output or automatic control through light
sensor. Sensitivity and time parameters are set through a partial
voltage resistor. All the signal processing is done on the chip.

Features

Digital signal processing

High power supply rejection ratio, anti-radio frequency interference(mobile phone,WiFi,etc.)

A second-order Butterworth bandpass filter with built-in infrared sensor to shield input interference at other frequencies

Sensitivity,Ontime, and light sensor Schmitt REL output.

Ontime adjustable

Good stability and effective suppression of repeated malfunctions

Low power consumption and simple application circuit


Technical Data

1.Absolute Maximum Ratings 

Electrical characteristics(beyond those listed below may cause permanent damage to the device. Exposure to absolute maximum ratings may affect the device reliability. )

Parameter

Symbol

Min

Max

Unit

Remarks

Operating Temp

TST

-30

70


Current into any pin

Into

-100

100

mA


Storage Temp

TST

-40

80


2. Operating Conditions (T=25°C, Vdd=3V,unless stated otherwise)

Parameter

Symbol

Min

Type

Max

Unit

Remarks

Regular voltage

VDD

2.2

3

3.7

V


Supply current

IDD

9

9.5

11

μA


Sensitivity threshold

VSENS

90


2000

μV


Detective Wavelength

λ

5


14

um


Outputs REL

Output current low

IOL

10



mA

VOL<1V

Output current high

IOH

-10



mA

VOH>(VDD-1V)

Low REL output locking time

TOL


2


s

Non-adjustable

High REL output delay time

TOH

2


3600

s


Inputs SENS, ONTIME

Input voltage range


0


VDD1/2

V

Adjustable between 0V and VDD/2

Input leakage current


-1


1

μA


Input OEN

Input low voltage

VIL

0.8V-1.2V (Hysteresis zone)


0.8

V

Voltage threshold from high to low

Input high voltage

VIH

1.2



V

Voltage threshold from low to high

Input current

II

-1


1

μA

VSS<VIN<VDD

Oscillator and Filter

Send a Message
Top